Abstract

The presented work shows the results of the monitoring campaign conducted on two Cross
Laminated Timber (CLT) test box equipped respectively with a micro ventilated facade
and a thermal coat technology. Specifically, the experimental work was performed in order
to compare the temperature levels of the Isotec® wall micro ventilated facade respect to
traditional ETICS, with two different thermal mass, for facade insulation. The results showed
that the micro ventilated façade, due to the shielding and air cavity comined effect contributes
to reduce the summer heat stress with lower internal heat loads.

Published
2018-11-06
How to Cite
SALVALAI, Graziano. Experimental analysis of different multilayer insulated façade. Tema: Technology, Engineering, Materials and Architecture, [S.l.], v. 4, n. 2, p. 25-35, nov. 2018. ISSN 2421-4574. Available at: <http://artecweb.org/ojs2/index.php/TeMA/article/view/187>. Date accessed: 19 nov. 2018. doi: https://doi.org/10.17410/tema.v4i2.187.